You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PPJBKAN


$566.90 USD
  • SUN HYDRAULICS
  • Material:PPJBKAN
  • Model:PPJB-KAN
  • Summary:Cartridge

Quantity in stock: 0

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPJBKAN (PPJBKAN) is a pilot-operated pressure reducing/relieving valve designed to manage high primary pressures at the inlet port 2, reducing them to a consistent lower pressure at port 1, while offering a full-flow relief function from port 1 to tank port 3. This valve is engineered with maximum pressure limitations at port 3 of up to 3000 psi (210 bar), and it directly adds pressure to the valve setting in a 1:1 ratio without exceeding this limit. It is important to note that pilot-operated valves are not fast-acting; for applications requiring superior dynamic response, direct acting valves are recommended. The Sun Hydraulics PPJBKAN is tested with different maximum inlet pressures based on adjustment ranges: Ranges D, E, N, and Q support up to a 2000 psi (140 bar) differential between inlet and reduced pressures, while ranges A, B, and H handle up to a 3000 psi (210 bar) differential. For ranges C and W, an inlet pressure of up to 5000 psi (350 bar) can be accommodated. The valve demonstrates exceptionally stable performance with low hysteresis due to its flat pressure-flow characteristics. This model allows for full reverse flow from reduced pressure port 1 back to inlet port 2 but may require an additional check valve if reverse free flow is necessary in the circuit. The PPJBKAN incorporates Sun's floating style construction which minimizes internal binding risks due to excessive installation torque or machining variations in cavity/cartridge configurations. Additional specifications include a Series-4 cavity T-19A with an operational capacity of up to 80 gpm (320 L/min), factory pressure settings established with blocked control ports, and a maximum operating pressure of 5000 psi (350 bar). The control pilot flow ranges between 15 - 20 in\u00b3/min (0.25 - 0.33 L/min), making it suitable for various hydraulic applications requiring precise pressure regulation.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-19A
Series4
Capacity80 gpm320 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 5/8 in.41,3 mm
Valve Installation Torque350 - 375 lbf ft474 - 508 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight3.10 lb1,40 kg
Seal kit - CartridgeViton: 990-019-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure