***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PPHFCCN (PPHFCCN) is a pilot-operated, pressure reducing-relieving valve designed to manage high primary pressure at the inlet port 2, reducing it to a consistent lower pressure at port 1. It also provides a full-flow relief function from port 1 to tank port 3. This valve features a main stage orifice drilled directly into the piston, enhancing its durability for demanding applications. It maintains stability with exceptionally flat pressure-flow characteristics and low hysteresis. The maximum allowable pressure at port 3 should not exceed 3000 psi (210 bar), and the recommended maximum inlet pressure varies based on adjustment ranges: D, E, N, and Q are tested up to a 2000 psi (140 bar) differential; A, B, and H up to 3000 psi (210 bar); and C and W up to 5000 psi (350 bar). The valve is suitable for applications requiring stable pressure regulation but is not ideal for scenarios demanding fast dynamic response; in such cases, direct acting valves are recommended. It incorporates Sun's floating style construction to minimize internal binding due to installation torque or machining variations. The PPHFCCN has a capacity of 40 gpm (160 L/min) and operates at a maximum pressure of 5000 psi (350 bar). It requires an installation torque of 150-160 lbf ft (203-217 Nm) and features an adjustment screw with an internal hex size of 5/32 in. For configurations requiring reverse flow from reduced pressure port 1 to inlet port 2, it is advised to consider adding a separate check valve in the circuit.

Pilot-operated, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3).

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-17A
Series3
Capacity40 gpm160 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/4 in.31,8 mm
Valve Installation Torque150 - 160 lbf ft203 - 217 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight1.30 lb0,60 kg
Seal kit - CartridgeViton: 990-017-006

Show FAQ