You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
CBGGRCN


$211.50 USD
  • SUN HYDRAULICS
  • Material:CBGGRCN
  • Model:CBGG-RCN
  • Summary:Cartridge

Due to extremely high demand, please call 888-905-7411 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBGGRCN (CBGGRCN) is a sophisticated counterbalance valve designed for controlling overrunning loads in hydraulic systems. This valve incorporates a check valve that permits free flow from the directional valve port 2 to load port 1, while a direct-acting, pilot-assisted relief valve manages flow from port 1 to port 2. The pilot assist at port 3 effectively reduces the relief valve setting according to the pilot ratio, enhancing the operational flexibility and efficiency of the system. The CBGGRCN is engineered to be set at least 1.3 times the maximum load-induced pressure to ensure stability and reliability in performance. Adjustments can be made by turning the setting clockwise to decrease and release load pressure, with a full clockwise setting being less than 200 psi (14 bar). It also features backpressure compensation at port 2 which adds to the effective relief setting proportionally. Designed for high-capacity applications, this valve can handle up to 60 gpm (240 L/min) and withstands a maximum recommended load pressure of up to 3850 psi (270 bar), with a maximum setting reaching up to 5000 psi (350 bar). The valves are built with EPDM seals suitable for phosphate ester fluids but should avoid exposure to petroleum-based substances which could damage these seals. Sun Hydraulics has equipped this model with positive seals between all ports and has ensured that it can be installed directly into cavities machined into actuator housings. This design not only protects the valve but also enhances circuit stiffness. Additionally, its floating style construction minimizes internal parts binding which could occur due to excessive installation torque or variations in cavity/cartridge machining. Overall, the Sun Hydraulics CBGGRCN offers robust performance features tailored for effective load control in dynamic hydraulic systems, ensuring reliability and precision in operations involving heavy-duty machinery and equipment.

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.

Other names for this valve include motion control valve and over center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • This valve has positive seals between all ports.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-17A
Series 3
Capacity 60 gpm240 L/min.
Pilot Ratio 4.5:14.5:1
Maximum Recommended Load Pressure at Maximum Setting 3850 psi270 bar
Maximum Setting 5000 psi350 bar
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic StandardStandard
Reseat >85% of setting>85% of setting
Valve Hex Size 1 1/4 in.31,8 mm
Valve Installation Torque 150 - 160 lbf ft203 - 217 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight 1.60 lb0,70 kg
Seal kit - Cartridge Viton: 990-017-006

Show FAQ