***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRHBCDN (PRHBCDN) is a direct-acting pressure reducing/relieving valve designed to maintain a consistent reduced pressure at port 1 while providing a full-flow relief function from port 1 to tank port 3. This valve features a damped construction for stable operation, allowing for the use of high reduced pressures. It is suitable for accumulator circuits due to its reduced secondary circuit leakage, as there is no pilot control flow. The valve's design ensures reliable operation even in contaminated systems and dead-headed conditions. However, it is not recommended for counterbalancing applications due to a transitional step between reducing and relieving modes that equals 5% of the high end of the adjustment range. The PRHBCDN valve can handle pressures up to 5000 psi (350 bar) and has a maximum valve leakage of 4 in\u00b3/min (65 cc/min) at 110 SUS (24 cSt). It incorporates Sun's floating style construction, which minimizes the risk of internal parts binding from excessive installation torque or cavity/cartridge machining variations. The valve supports full reverse flow from reduced pressure port 1 to inlet port 2, although adding a separate check valve may be necessary if reverse free flow is required in the circuit. The cartridge is physically interchangeable with other three-port pressure reducing and relieving cartridges of the same frame size, facilitating easy integration into existing systems. This model includes EPDM seals suitable for use with phosphate ester fluids but should not be exposed to petroleum-based fluids, greases, or lubricants as they can damage the seals. The PRHBCDN allows for an adjustment range with up to five clockwise turns required to increase settings and can be installed with a torque between 150 - 160 lbf ft (203 - 217 Nm).

Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Unlike pilot operated versions, direct acting valves exhibit a transitional step between reducing and relieving modes. This step equals 5% of the high end of the adjustment range, independent of the valve setting. Therefore, these valves may not be suitable for counterbalancing applications.
  • Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-17A
Series3
Capacity40 gpm160 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)4 in³/min.65 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/4 in.31,8 mm
Valve Installation Torque150 - 160 lbf ft203 - 217 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight1.50 lb0,70 kg
Seal kit - CartridgeViton: 990-017-006