PBFBLNN/LH


$135.10 USD
  • SUN HYDRAULICS
  • Material:PBFBLNN/LH
  • Model:PBFB-LNN/LH
  • Summary:Cartridge

Due to extremely high demand, please call 888-905-7411 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PBFBLNN/LH (PBFBLNN/LH) is a pilot-operated, pressure-reducing valve designed to regulate high primary pressure at inlet port 2 to maintain a constant reduced pressure at port 1. This feature allows circuits with varying pressure requirements to operate efficiently using a single pump. The valve is interchangeable with all three-port pressure reducing and reducing-relieving cartridges, sharing the same flow path and cavity for similar frame sizes. It is recommended to use a full-capacity return line port 3 with reducing-relieving cartridges for optimal performance. The valve's main stage orifice is protected by a 150-micron stainless steel screen, ensuring durability and reliability. The recommended maximum inlet pressure varies based on the adjustment range: ranges D, E, N, and Q are tested with a maximum differential of 2000 psi (140 bar) between inlet and reduced pressure, while ranges A, B, and H can handle up to 3000 psi (210 bar). Ranges C and W are tested at an inlet pressure of up to 5000 psi (350 bar). The PBFBLNN/LH valve exhibits exceptionally flat pressure-flow characteristics with low hysteresis and stability. It also includes Sun's floating style construction to prevent internal parts from binding due to excessive installation torque or machining variations. Designed for systems that require precise control over hydraulic pressures, this valve is suitable for applications where pilot flow consumption is critical. If superior dynamic response is needed, direct-acting valves may be considered as an alternative. This model incorporates EPDM seals suitable for systems using phosphate ester fluids but should not be exposed to petroleum-based substances. The valve's adjustable settings allow it to be tailored throughout its full range using W or Y controls unless a special setting specifies the maximum setting of the valve.

Pilot-operated, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, allowing circuits with multiple pressure requirements to be operated using a single pump.

  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • If pilot flow consumption is critical, consider using direct acting reducing/relieving valves.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity20 gpm80 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow10 - 15 in³/min.0,16 - 0,25 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.60 lb0,30 kg
Seal kit - CartridgeViton: 990-202-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) N and Q are 2000 psi (140 bar) W is 5000 psi (350 bar)inlet pressure