$98.40 USD
  • SUN HYDRAULICS
  • Material:CBAHLCN/LH
  • Model:CBAH-LCN/LH
  • Summary:Cartridge

Quantity in stock: 0

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics CBAHLCN/LH (CBAHLCN/LH) is a counterbalance valve designed to manage overrunning loads effectively in various hydraulic systems. This model features a check valve that allows free flow from the directional valve port to the load port, while a direct-acting, pilot-assisted relief valve controls flow from port to port. The pilot assist at the specified port reduces the effective setting of the relief valve, which is contingent on the pilot ratio. This particular model is engineered for settings that are at least 1.3 times the maximum load-induced pressure, ensuring reliable performance under demanding conditions. The valve can be adjusted by turning clockwise to decrease setting and release load; its full clockwise setting reaches up to 350 psi (24 bar). Additionally, backpressure at one of the ports adds to the effective relief setting by a factor of 1 plus the pilot ratio times the backpressure. The CBAHLCN/LH incorporates Sun's floating style construction which minimizes potential internal parts binding due to excessive installation torque or cavity/cartridge machining variations. It has a capacity of 3.8 gpm (14 L/min) and offers a pilot ratio of 4:1, making it suitable for applications requiring precise load control with minimal leakage. The design allows for easy integration directly into an actuator housing cavity which enhances protection and circuit stiffness. It also supports two check valve cracking pressures to accommodate different system needs without actuator cavitation concerns. The model ensures positive seals between all ports and maintains compatibility across all port counterbalance, load control, and pilot-to-open check cartridges within a given frame size. This versatility makes it an ideal choice for systems requiring robust control and reliable operation in dynamic hydraulic environments.

Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.

Other names for this valve include motion control valve and over center valve.

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Restrictive valves have no relief capacity other than as a thermal relief.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is 200 psi (14 bar).
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • This valve has positive seals between all ports.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-11A
Series 1
Capacity 2.5 gpm10 L/min.
Pilot Ratio 10:110:1
Maximum Recommended Load Pressure at Maximum Setting 3850 psi270 bar
Maximum Setting 5000 psi350 bar
Pilot Configuration SealedSealed
Factory Pressure Settings Established at 2 in³/min.30 cc/min.
Maximum Valve Leakage at Reseat 5 drops/min.0,3 cc/min.
Adjustment - Number of Counterclockwise Turns to Increase Setting 3.753.75
Operating Characteristic Ultra-restrictiveUltra-restrictive
Reseat >85% of setting>85% of setting
Valve Hex Size 7/8 in.22,2 mm
Valve Installation Torque 30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size 5/32 in.4 mm
Locknut Hex Size 9/16 in.15 mm
Locknut Torque 80 - 90 lbf in.9 - 10 Nm
Model Weight .35 lb0,15 kg