You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

HYDRAFORCE
EC16-42-0-N-150
5439501


$91.75
  • HYDRAFORCE
  • Material:5439501
  • Model:EC16-42-0-N-150 COMPENSATOR
  • Summary:PRIORITY ON DEMAND PRESSURE COMPENSATOR WITH STATIC LOAD SENSE

Quantity in stock: 4

Description EC16-42 is a screw-in, cartridge style, priority on demand pressure compensator valve with static load sense. Intended to provide priority flow in required amount, while allowing excessive flow to be used for auxiliary functions. Operation With inlet flow at port 3, the EC16-42 will deliver required priority flow at port 4 regardless of load pressure. Excessive flow exits at port 2 and port 1 is the load sense port. All ports may be fully pressurized. Features Priority-on-demand Static load sense Hardened parts for long life. Quiet, modulated response. Industry-common cavity.

Properties: Unit weight: 0.67 kg (1.48 lb)

Internal wetted surface area: 425 cm² (65.9 in²)

Ratings: Pressure Ratings
Pressure rating: 241 bar (3500 psi)

Proof pressure: 690 bar (10000 psi)

Burst pressure: 1275 bar (18500 psi)

Flow Ratings
Inlet flow rating: 115 lpm (30.0 gpm)
Maximum, with compensating spring 5.5 bar (80 psi)
150 lpm (40.0 gpm)
Maximum, with compensating spring 10.3 bar (150 psi)
189 lpm (50.0 gpm)
Maximum, with 15.2 bar (220 psi)

Priority flow rating: 80% of input flow when priority pressure exceeds bypass pressure; 50% of
input flow when bypass pressure exceeds priority pressure

Temperature Ratings
Operating fluid temperature: -40 to 100 °C (-40 to 212 °F)
With buna N seals
-26 to 204 °C (-15 to 400 °F)
With fluorocarbon seals
-54 to 107 °C (-65 to 225 °F)
With polyurethane seals
-54 to 107 °C (-65 to 225 °F)
With urethane seals

Storage temperature: -40 to 70 °C (-40 to 160 °F)

Ambient temperature: -40 to 70 °C (-40 to 160 °F)

Other Ratings
Corrosion protection: 960 hr salt spray per ASTM b117 (gec16-42)

Operating Parameters: Fluids: Mineral based or synthetic hydraulic fluid with lubricating
properties

Fluid viscosity range: 7.4 to 420 cSt

Maximum operating contamination level: 18/16/13 per ISO 4406

Performance: https://www.hydraforce.com/globalassets/product-images/ec16-42_flow-pressure2022-02-24.gif
https://www.hydraforce.com/globalassets/product-images/ec16-42_pressure-drop2022-02-24.gif


Installation Specifications: Cavity: VC16-4
16-size-4-way Cavities
Cartridge installation torque: 133 to 138 N-m (98 to 102 ft-lb)

Orientation restriction: None

Order Code: POSITION CODE DESCRIPTION EC16-42-H-J-R H Line Body H 0 No Body H 12TD Ductile Iron SAE 12 H 16TD Ductile Iron SAE 16 J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane R Compensator Spring R 80 80 Compensator Spring R 150 150 Compensator Spring R 220 220 Compensator Spring

Dimensions: https://www.hydraforce.com/globalassets/product-images/ec16-42_dim2022-02-24.gif


Accessories: Seal kit: SK16-4X-MMM
X = seal option
SK10-4U-O
Urethane
Seal kit installation instructions
Housings:
Available
16-4w valve bodies