You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

HYDRAFORCE
5040174


$345.25 USD
  • HYDRAFORCE
  • Material:5040174
  • Model:SV12-P23A-0-N-24DG-M3 SOLENOID
  • Summary:SOLENOID CARTRIDGE VALVE POPPET, 2 PORT, NORMALLY OPEN WITH INTEGRAL POSITION SENSOR

Due to extremely high demand, please call 888-905-7411 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Hydraforce directly.***
The Hydraforce 5040174 (5040174) is a solenoid-operated, 2-port, normally open, poppet-type, screw-in hydraulic cartridge valve. This valve is specifically designed to function as a load holding or blocking valve in systems that require low internal leakage. The operation of this valve is straightforward: when de-energized, the SVPAX allows flow from port 1 to port 2 and vice versa. Upon energization, the valve closes to block flow from port 1 to port 2 while allowing flow from port 2 to port 1 after overcoming the solenoid force. Key features of the Hydraforce 5040174 include an integral position sensor that indicates when the valve has shifted, making it easier for system monitoring and diagnostics. The continuous-duty rated coil ensures reliable operation even under prolonged usage. The valve seat is hardened for enhanced durability and minimal leakage over its lifespan. It also offers optional coil voltages and terminations to accommodate diverse system requirements. The efficient wet-armature construction contributes to the robust performance of the valve. Cartridges are designed to be voltage interchangeable which provides flexibility in system design and upgrades. Furthermore, the waterproof E-Coils are rated up to IP69K ensuring protection against ingress of dust and high temperature high-pressure water jets. The unitized, molded coil design enhances structural integrity while the solenoid tubes and coils are treated for corrosion resistance with a 500-hour salt-spray rating, making them suitable for challenging environments.

Unit weight: 0.61 kg (1.35 lb)
SV12-P23A

Internal wetted surface area: 302 cm² (46.8 in²)

RatingsPressure Ratings
Pressure rating: 207 bar (3000 psi)

Proof pressure: 345 bar (5000 psi)

Burst pressure: 827 bar (12000 psi)

Flow Ratings
Flow rating: 113.6 lpm (30 gpm)

Maximum internal leakage: 5 drops/min
Max at 207 bar (3000 psi)
0.4 lpm (0.1 gpm)
Typical flow (leakage) in transition at 207 bar (3000 psi). (see "Flow
vs % Valve Shift" graph for flow in transition from valve close to valve
open).

Other Ratings
Response: 61 ms
Pull-in. Response times measured per NFPA/T3.5.30-2008 *Inlet pressure
at port 2 is 207 bar (3000 psi) *Valve oriented vertically and purged of
air
202 ms
Drop-out. Response times measured per NFPA/T3.5.30-2008 *Inlet pressure
at port 2 is 207 bar (3000 psi) *Valve oriented vertically and purged of
air

Minimum pull-in voltage: 10.2 Vdc
12 Vdc coil

Temperature Ratings
Operating fluid temperature: -40 to 100 °C (-40 to 212 °F)
With buna N seals
-26 to 204 °C (-15 to 400 °F)
With fluorocarbon seals *See Position sensor operating
temperature*
-54 to 107 °C (-65 to 225 °F)
With urethane seals *See Position sensor operating
temperature*

Storage temperature: -40 to 70 °C (-40 to 160 °F)

Ambient temperature: -40 to 70 °C (-40 to 160 °F)

Position sensor operating temperature: -40 to 110 °C (-40 to 230 °F)
Sensor element operating temperature limits the operating temperature of
the entire assembly
Operating ParametersFluids: Mineral based or synthetic hydraulic fluid with lubricating
properties

Fluid viscosity range: 7.4 to 420 cSt

Maximum operating contamination level: 20/18/14 per ISO 4406
Performancehttps://www.hydraforce.com/globalassets/product-images/sv12-p23a_perf12022-02-24.gif
https://www.hydraforce.com/globalassets/product-images/sv12-p23a_perf22022-02-24.gif

Installation SpecificationsCavity: VC12-2
12-size-2-way Cavities
Cartridge installation torque: 44.9 to 50.3 N-m (33 to 37 ft-lb)

Coil nut torque: 5.8 to 9.5 N-m (5 to 7 ft-lb)

Orientation restriction: None
Order CodePOSITION CODE DESCRIPTION SV12-P23AE-H-J-L-M E Manual Override E BLANK NONE E K Momentary Push Override, Knob E P Momentary Push Override, Button H Line Body H 0 No Body H 10T Aluminum SAE 10 H 12T Aluminum SAE 12 H 16T Aluminum SAE 16 H 12TD Ductile Iron SAE 12 H 16TD Ductile Iron SAE 16 H 8B Aluminum BSPP 1" (8) H 8BD Ductile Iron BSPP 1" (8) J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane L Coil L 0 No Coil L 10DG 10 VDC, D-Coil, DIN 43650 L 10DL 10 VDC, D-Coil, Dual Lead Wires L 10DR/D 10 VDC, D-Coil, Deutsch with Diode L 10DS 10 VDC, D-Coil, Dual Spade L 10EL 10 VDC, E-Coil, Dual Lead Wires L 10ER 10 VDC, E-Coil, Deutsch L 10ER/Z 10 VDC, E-Coil, Deutsch with Zener Diode L 12DG 12 VDC, D-Coil, DIN 43650 L 12DL 12 VDC, D-Coil, Dual Lead Wires, 18 inches long L 12DL/36 12 VDC, D-Coil, Dual Lead Wires, 36 inches long L 12DL/W 12 VDC, D-Coil, Dual Lead Wires with Weatherpak L 12DL/W/D 12 VDC, D-Coil, Dual Lead Wires with Weatherpak with Diode L 12DR 12 VDC, D-Coil, Deutsch L 12DR/D 12 VDC, D-Coil, Deutsch with Diode L 12DR/Z 12 VDC, D-Coil, Deutsch with Zener Diode L 12DS 12 VDC, D-Coil, Dual Spade L 12EG 12 VDC, E-Coil, DIN 43650 L 12EJ 12 VDC, E-Coil, AMP Jr. L 12EL 12 VDC, E-Coil, Dual Lead Wires, 18 inches long L 12EL/36 12 VDC, E-Coil, Dual Lead Wires, 36 inches long L 12EL/W/Z 12 VDC, E-Coil, Dual Lead Wires with WeatherPak and Zener Diode L 12EL/Z 12 VDC, E-Coil, Dual Lead Wires with Zener Diode L 12ER 12 VDC, E-Coil, Deutsch L 12ER/Z 12 VDC, E-Coil, Deutsch with Zener Diode L 12EY 12 VDC, E-Coil, Metri-Pack 150 L 12EY/Z 12 VDC, E-Coil, Metri-Pack 150 with Zener Diode L 20DR/D 20 VDC, D-Coil, Deutsch with Diode L 20DS 20 VDC, D-Coil, Dual Spade L 20ER 20 VDC, E-Coil, Deutsch L 24AG 24 VDC, D-Coil, DIN 43650 L 24AP 24 VDC, D-Coil, 1/2" Conduit and Dual Lead Wires L 24DG 24 VDC, D-Coil, DIN 43650 L 24DL 24 VDC, D-Coil, Dual Lead Wires L 24DL/W 24 VDC, D-Coil, Dual Lead Wires with Weatherpak L 24DL/W/D 24 VDC, D-Coil, Dual Lead Wires with Weatherpak with Diode L 24DP 24 VDC, D-Coil, 1/2" Conduit and Dual Lead Wires L 24DR 24 VDC, D-Coil, Deutsch L 24DR/D 24 VDC, D-Coil, Deutsch with Diode L 24DS 24 VDC, D-Coil, Dual Spade L 24EG 24 VDC, E-Coil, DIN 43650 L 24EJ 24 VDC, E-Coil, AMP Jr. L 24EL 24 VDC, E-Coil, Dual Lead Wires, 18 inches long L 24EL/36 24 VDC, E-Coil, Dual Lead Wires, 36 inches long L 24EL/W/Z 24 VDC, E-Coil, Dual Lead Wires with WeatherPak and Zener Diode L 24ER 24 VDC, E-Coil, Deutsch L 24ER/Z 24 VDC, E-Coil, Deutsch with Zener Diode L 24EY 24 VDC, E-Coil, Metri-Pack 150 L 24EY/Z 24 VDC, E-Coil, Metri-Pack 150 with Zener Diode L 36DS 36 VDC, D-Coil, Dual Spade L 115AG 115 VAC, D-Coil, DIN 43650 L 115AP 115 VAC, D-Coil, 1/2" Conduit and Dual Lead Wires L 230AG 230 VAC, D-Coil, DIN 43650 L 230AP 230 VAC, D-Coil, 1/2" Conduit and Dual Lead Wires M Position Sensor Termination M BLANK No Position Sensor M M3 Neutral Sense, M12-4P, Dual Output NC/NO M N3 Neutral Sense, DT04-4P, Dual Output NC/NO
Position Sensor SpecificationsElectrical Parameters
Supply voltage: 9 to 32 Vdc
Vcc

Output voltage with target present: Vcc

Output clamp current: 40 to 65 mA
For Vcc up to 32 Vdc

Ratings
ESD: ±8 kV
Air discharge

EMI: 30 V/m
From 400 MHz to 2 GHz

IP rating: IP67

Vibration: 10 G
10 to 2000 Hz sinosudial

Mechanical shock: 50 G
11 ms, half-wave sinosudial

Position sensor operating temperature: -40 to 110 °C (-40 to 230 °F)
Sensor element operating temperature limits the operating temperature of
the entire assembly

Properties
Connector: Deutsch DT04-4P
Option N3 (dual output)
M12
Option M3 (dual output)
Wiring Diagramshttps://www.hydraforce.com/globalassets/product-images/hsv10-p20a_sym22022-02-24.gif
https://www.hydraforce.com/globalassets/product-images/hsv10-p20a_sym32022-02-24.gif

https://www.hydraforce.com/globalassets/product-images/sv12-p23a_dim12022-02-24.gif
https://www.hydraforce.com/globalassets/product-images/sv12-p23a_dim22022-02-24.gif


Seal kit: SK12-2X-T
X = Seal option
Seal kit installation instructions
Housings:
Available
12-2w valve bodies
Coils:
10 size E
coils
10 size D
coils